Aritech ATS4000 Servisní příručka Strana 66

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 83
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 65
66 ATS Designers Guide
Table 4-12 Mapping zones and outputs in the elevator controller.
Elevator – local
address
First input First zone
Elevator 1 1 1
Elevator 2 65 65
Elevator 3 129 129
Elevator 4 193 193
4.5 Cards and Readers
4.5.1 Advisor MASTER System Readers
The list of ATS system devices that can serve as user interface for access control is
contained in Table 1-10. These are keyboards, readers, keyboards with integrated
readers and the interface to connect other readers. Each of these devices can be used
for user verification in access control and a significant simplification is the ability to
connect them directly to the system or local bus. This decreases the complexity of the
wiring and reduces the installation time. The smart cards and readers offered with the
ATS system deserve special attention. They have been described in detail in chapter
6. ATS system Smart Cards.
4.5.2 Other readers
Often the system design guidelines contain specific requirements as to the type of access
control cards and readers. The ATS systems can use any reader compatible with the
Wiegand hardware interface, and any card or token that sends a data stream of up to 48
bits. The details of using cards of different formats are described in paragraph 0. To
connect a Wiegand interface reader to the ATS system the ATS1170 interface, or any of
the reader outputs of the ATS1250/60 need to be used – it has to be kept in mind, that
the maximum distance from the reader to the interface cannot exceed 70m, see section
3.2 which describes the wiring. The method of connecting the devices to the control panel
– the system bus – or access control DGP – local bus and ATS125 reader inputs – has
been detailed in the following paragraphs.
4.5.2.1 HID
HID readers use the Wiegand interface. They can be used in the Advisor Master system
by connecting them to the system, to the direct reader inputs of the access control DGP,
or through the ATS1170 to the system bus, as well as the access control DGP local bus
see Drawing 4-6. This method can be used to connect any Wiegand interface reader..
Control panel
A
TS1170
HID
ATS1250/60
HID
HID
HID
HID
A
TS1170
HID
A
TS1170
HID
System bus
Local bus
Drawing 4-6 Connecting the Wiegand interface readers to the ATS system.
Zobrazit stránku 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 ... 82 83

Komentáře k této Příručce

Žádné komentáře